100×200 Cable Tray
Cable trays are divided into slot type, tray type, ladder type, and grid type structures, consisting of brackets, brackets, and installation accessories. The bridge inside the building can be erected independently or laid on various buildings (structures) and pipe rack supports. It should reflect the characteristics of simple structure, beautiful appearance, flexible configuration, and convenient maintenance. All parts need to be galvanized and installed on the outdoor bridge outside the building.

PRODUCT PARAMETERS

Cable trays are divided into slot type, tray type, ladder type, and grid type structures, consisting of brackets, brackets, and installation accessories. The bridge inside the building can be erected independently or laid on various buildings (structures) and pipe rack supports. It should reflect the characteristics of simple structure, beautiful appearance, flexible configuration, and convenient maintenance. All parts need to be galvanized and installed on the outdoor bridge outside the building.


Selection of cable tray

1. In engineering design, the layout of the bridge should be comprehensively compared based on factors such as economic rationality, technical feasibility, and operational safety to determine the optimal plan. It should also fully meet the requirements of construction, installation, maintenance, and cable laying.

2. When the cable tray is horizontally laid, the height from the ground should generally not be less than 2.5m. When vertically laid, the part below 1.8m from the ground should be protected with a metal cover plate, except when laid in an electrical dedicated room. If the cable tray is horizontally laid in the equipment interlayer or pedestrian walkway and is below 2.5m, protective grounding measures should be taken.

3. When using cable trays, trunking, and their supports and hangers in corrosive environments, they should be made of corrosion-resistant rigid materials or undergo anti-corrosion treatment. The anti-corrosion treatment method should meet the engineering requirements

Environmental and durability requirements. For places with high requirements for corrosion resistance or cleanliness, aluminum alloy cable trays should be selected.

4. In sections with fire protection requirements, cable ladders and trays can be added with fire-resistant or flame retardant materials such as boards, nets, etc. to form a closed or semi closed structure. Measures such as applying fire-resistant coatings to the surface of the cable tray and its supports and hangers should be taken, and its overall fire resistance performance should meet the requirements of relevant national regulations or standards. Aluminum alloy cable trays should not be used in places with high fire protection requirements in engineering.

5. Cable lines that need to be shielded from electromagnetic interference, or when there are environmental requirements such as outdoor sunlight, oil, corrosive liquids, flammable dust, etc. for external protection, non perforated tray type cable trays should be selected.

6. In places prone to dust accumulation, cable trays should use cover plates; In public passages or outdoor crossing road sections, it is advisable to add pads or use perforated trays on the bottom bridge.

7. Cables with different voltages and purposes should not be laid in the same layer of cable tray.


Description

Model

Height

Width

CT50x100

50

100

CT75x150

75

150

CT100x200

100

200

CT100x300

100

300

CT100x400

100

400

CT100x500

100

500

CT100x600

100

600

CT100x800

100

800

CT150x250

150

250

CT150x300

150

300

CT150x400

150

400

CT150x500

150

500

CT150x600

150

600

CT150x800

150

800

CT200x400

200

400

CT200x500

200

500

CT200x600

200

600

CT200x800

200

800


P/N Definition:

◆ CT50×100, CT stands for cable trunking, 50×100 stands for height 50mm × width 100mm (outer dimension).


Sectional View


Size

Section

100×200

1725008958688071202573971456.png 

 100×300

1725008934688071103391277056.png 

 100×400

1725008939688071122366296064.png 

 100×500

1725008944688071143862104064.png 

 100×600

1725008949688071163634053120.png






Product Packaging

蒙版组 1@1x

FAQ

Q1. What is your terms of Packing?

A: Generally we pack your goods with Neutral English bag, PP Woven bag with PE inner bag. If you have your own legally registered sack design, we can pack your goods with your brand and design bags after getting your authorization letter.

Q2. What is your terms of payment?

A: Normally 30% TT as deposit in advance, and 70% TT after email the copy of BL. Or LC at sight. We'll show you the photos pf your goods and package before you arrange the payment.

Q3. What is your terms of delivery?

A: Normally we do FOB, CFR, CIF terms.

Q4. How about your delivery date?

A: Normally it will takes 10~15 days after receive the deposit. The specific delivery time depends on the items and the quantity of the order.

Q5. Can you produce according to the sample?

A: Yes, we can produce by your samples or the specification you provide.

CONTACT US

PRODUCT RECOMMENDATION